Skip to main content

Also called: Haematology analyser, FBC machine, CBC analyzer, Mesin FBC

Haematology Analyser (FBC Machine) Supplier in Malaysia

Full blood count analysers for GP clinics, polyclinics, private hospitals and laboratories — 3-part and 5-part differential, matched to your daily sample count and quoted in writing by AA Alive.

Last updated:

3-part white-cell histogramWhite cells sorted by volume: a tall lymphocyte peak near 70 femtolitres, a small mid-cell group, and a broad granulocyte peak near 190 femtolitres.0100200300400cell volume, fLLymphMidGran
3-part WBC histogram with discriminators (illustrative)
Both analyser classes explained and quoted
3-part and 5-part
Quoted at your real daily volume, start-up reagent included
Cost per test
Batu Caves, Kota Kinabalu and Kuching
3 branches
Every analyser and reagent we quote
MDA-registered

What a haematology analyser does

A haematology analyser counts and sizes the cells in a small sample of EDTA whole blood and reports the full blood count (FBC), also called the complete blood count (CBC). “Haematology analyser”, “hematology analyzer”, “FBC machine”, “CBC machine”, “blood cell counter” and “mesin FBC” all mean the same instrument.

Red cells

RBC count, haemoglobin (HGB), haematocrit (HCT) and the red-cell indices MCV, MCH, MCHC and RDW — the core of anaemia work-up.

White cells

Total WBC count plus a differential: three groups on a 3-part analyser, five cell types on a 5-part analyser.

Platelets

Platelet count (PLT) and indices such as MPV — essential for dengue monitoring, which is a daily reality for Malaysian clinics.

3-part vs 5-part differential

How the two classes of analyser compare
3-part analyser5-part analyser
White-cell groupsLymphocytes, mid-sized cells, granulocytesNeutrophils, lymphocytes, monocytes, eosinophils, basophils
MethodElectrical impedance (cell size)Impedance plus laser flow cytometry or cytochemistry
Typical parametersAbout 19–21About 23–30+
ReagentsUsually 3 (diluent, lyse, cleaner)Usually 4–6
Best forGP clinics, small polyclinics, rural labsHospitals, busy labs, specialist clinics
Running costLowerHigher per test

How to choose an FBC machine

  • Count your FBCs per day today and in two years — throughput and reagent pack sizes should match it.
  • Decide whether a 3-part differential answers your clinical questions or you need eosinophils, monocytes and basophils reported separately.
  • Ask for the real cost per test at 5, 10 and 20 samples a day, including the reagent used at daily start-up and shutdown.
  • Check whether reagents are closed (only the maker’s) or open, and how long opened reagents last.
  • Check sample volume and whether a pre-diluted capillary (finger-prick) mode is available for children.
  • Ask how results reach your clinic system — LIS/HIS connection, USB export or printout.
  • Ask who supplies controls, how often calibration is due and the service response time in your state.
  • Ask for the MDA registration numbers of the analyser and its reagents.

Quality control from day one

Daily controls

Run commercial control blood (usually low, normal and high levels) before patient samples and record the results on a Levey-Jennings chart.

Calibration

Calibrate at installation, after major repairs and at the interval the manufacturer specifies.

External quality assessment

Join an EQA programme so your results are compared with other labs. Laboratories seeking accreditation do this under MS ISO 15189.

MDA registration for analysers and reagents

Haematology analysers and their reagents are in-vitro diagnostic (IVD) medical devices. Under the Medical Device Act 2012 (Act 737), a medical device must be registered with the Medical Device Authority (MDA) before it is imported, exported or placed on the Malaysian market — so ask for the registration number of the analyser and its reagents and check them on the MDA’s public register before you buy.

How we quote

  • You tell us your facility type, daily FBC count, staff and location.
  • We shortlist 3-part or 5-part analysers that fit, with an honest view of running costs.
  • You get a written quotation listing the analyser, reagents, controls, installation, training, LIS connection and warranty separately.
  • At installation the analyser is calibrated, controls are run with your staff and QC records are set up.

How to buy a haematology analyser in five steps

The order we work through with every clinic and lab so the analyser fits your volume and budget for years, not just on delivery day.

  1. Count your FBCs

    Note FBCs per day today and expected in two years, plus peak days such as dengue season.

  2. Pick 3-part or 5-part

    Decide whether you need eosinophils, monocytes and basophils reported separately.

  3. Get cost per test

    Ask each supplier for cost per reportable FBC at 5, 10 and 20 samples a day, including start-up, shutdown and controls.

  4. Check support and registration

    Confirm reagent supply and service in your state, and MDA registration for analyser and reagents.

  5. Install, calibrate, run QC

    Calibrate on site, run controls with your staff and set up QC records before the first patient.

Buyer’s guides

Key terms explained

Haematology analyser
An automated instrument that counts and sizes blood cells and reports the full blood count.
FBC / CBC
Full blood count / complete blood count — the same panel of red-cell, white-cell and platelet results.
3-part differential
White cells sorted by size into lymphocytes, mid-sized cells and granulocytes.
5-part differential
White cells reported as neutrophils, lymphocytes, monocytes, eosinophils and basophils.
Impedance (Coulter principle)
Counting and sizing cells by the change in electrical resistance as each passes through a small aperture.
Flow cytometry
Measuring cells by laser light scatter and fluorescence as they pass a beam; used by 5-part analysers.
HGB
Haemoglobin concentration, the key number for anaemia.
HCT
Haematocrit — the share of blood volume made up of red cells; watched closely in dengue.

Frequently asked questions

What is the difference between an FBC machine and a haematology analyser?
Nothing — they are the same instrument. FBC (full blood count) and CBC (complete blood count) are the test; the haematology analyser is the machine that runs it.
Is a 3-part haematology analyser enough for a GP clinic?
For most GP clinics, yes. A 3-part analyser gives the full red-cell and platelet picture plus three white-cell groups, which covers anaemia, infection screening and dengue platelet monitoring.
How much blood does a haematology analyser need?
Typically 10 to 20 microlitres of EDTA whole blood in open-tube mode. Many analysers also offer a pre-diluted mode for finger-prick samples.
How many samples per hour can an FBC machine run?
Compact 3-part analysers commonly run around 40 to 60 samples an hour; laboratory 5-part analysers run more. For a clinic, reagent cost matters more than speed.
What reagents does a haematology analyser use?
A 3-part analyser usually needs a diluent, a lysing reagent and a cleaner. 5-part analysers add further lyse and stain reagents. You also need control blood for daily QC.
Do haematology analysers need MDA registration?
Yes. The analyser and its reagents are in-vitro diagnostic medical devices and must be registered with the Medical Device Authority before they are sold in Malaysia.
Do you publish haematology analyser prices?
No. The price depends on 3-part or 5-part, brand, reagent package, connectivity and the exchange rate, so we quote in writing for your configuration.

Get a written quotation

Tell us your clinic or lab type, daily workload and location. We match suitable models and send a written quotation with delivery, installation and training spelled out.